set security zones security-zone trust interfaces t1-1/0/0.0 host-inbound-traffic protocols
all
For E1 interfaces:
set security zones security-zone trust interfaces e1-1/0/0.0 host-inbound-traffic protocols
all
Set security policies:
set security policies default-policy permit-all
NOTE: You can use the CLI commands set interfaces t1–1/0/0 or set interfaces
e1–1/0/0 to enable the 1-Port T1/E1 Mini-PIM to function as a T1 or an E1
interface.
Related
Documentation
1-Port T1/E1 Mini-Physical Interface Module Overview on page 81
1-Port T1/E1 Mini-Physical Interface Module Hardware Specifications on page 82
1-Port T1/E1 Mini-Physical Interface Module Network Interface Specifications on page 82
1-Port T1/E1 Mini-Physical Interface Module Supported Standards on page 83
1-Port T1/E1 Mini-Physical Interface Module LEDs on page 84
1-Port T1/E1 Mini-Physical Interface Module Supported Loopback Diagnostics on page 85